2019 Pittsburgh AISTech

Collection Main Crossover Valve Pressure Control (Room 403)

06 May 19
10:00 AM - 10:30 AM

Tracks: Cokemaking

Speaker(s): Mark Ferra, REXA
Collection main pressure control is a critical application in cokemaking. Gases generated during charging create pressure surges, requiring accurate positioning of the crossover valve to maintain the collection main pressure setpoint. REXA’s patented hydraulic actuation technology is able to react (3-5 Hz) to small, constantly varying changes in control signal with a repeatability of <0.1% travel position. REXA has improved pressure control while also reducing maintenance costs. The recovery time to return to the pressure setpoint improved by ~15%. The results are unique in that the REXA can maintain setpoint +/- 1 MMWC pressure.